Criteria for receiving left ventricular assist devices as destination therapy
Centers for Medicare and Medicaid Services Criteria |
New York Heart Association class IV (severe limitations) |
Intra-aortic balloon pump (> 7 days) (or peak VO2 < 14 mL/kg/min) |
No response to medical therapy |
Left ventricular ejection fraction < 25% |
Adequate right ventricular function |
Major contraindications to heart transplant |
Smoking cessation < 6 months |
Substance dependency |
Inadequate decision-making capacity |
Irreversible pulmonary hypertension (> 5 Wood units) |
Psychosocial issues |
Other end-organ issues |