[HTML][HTML] Percutaneous implantation of an entirely intracardiac leadless pacemaker

VY Reddy, DV Exner, DJ Cantillon… - … England Journal of …, 2015 - Mass Medical Soc
Background Cardiac pacemakers are limited by device-related complications, notably
infection and problems related to pacemaker leads. We studied a miniaturized, fully self-contained …

Smartwatch algorithm for automated detection of atrial fibrillation

…, CT Lambert, AA Hussein, DJ Cantillon… - Journal of the American …, 2018 - jacc.org
Background : The Kardia Band (KB) is a novel technology that enables patients to record a
rhythm strip using an Apple Watch (Apple, Cupertino, California). The band is paired with an …

Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator

DJ Cantillon, KG Tarakji, DJ Kumbhani, NG Smedira… - Heart rhythm, 2010 - Elsevier
BACKGROUND: Ventricular tachyarrhythmia events (VTE) are common among refractory
heart failure patients requiring ventricular assist device (VAD) support. It is unknown whether …

2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry

…, P Aziz, P Balsam, A Baranchuk, DJ Cantillon… - Heart rhythm, 2017 - Elsevier
Ambulatory ECG (AECG) is very commonly employed in a variety of clinical contexts to detect
cardiac arrhythmias and/or arrhythmia patterns which are not readily obtained from the …

Programming cardiac resynchronization therapy for electrical synchrony: reaching beyond left bundle branch block and left ventricular activation delay

…, C Pappone, J Mangual, D Cantillon… - Journal of the …, 2018 - Am Heart Assoc
Background QRS narrowing following cardiac resynchronization therapy with biventricular (BiV)
or left ventricular (LV) pacing is likely affected by patient‐specific conduction …

[PDF][PDF] of premature ventricular complexes

DJ Cantillon - Cleveland Clinic journal of medicine, 2013 - scholar.archive.org
. ABSTRACT Premature ventricular complexes (PVCs) are a common cause of palpitations.
Related symptoms include difficulty breathing, chest pain, fatigue, and dizziness. PVCs are …

Incidence and predictors of right ventricular pacing-induced cardiomyopathy in patients with complete atrioventricular block and preserved left ventricular systolic …

…, WI Saliba, N Varma, BL Wilkoff, DJ Cantillon - Heart rhythm, 2016 - Elsevier
… Dr Cantillon has received compensation for services rendered to St. Jude Medical; serves
on speakers bureau for Boston Scientific and St. Jude Medical; and has received research …

A dual-chamber leadless pacemaker

…, L Ganz, C Hubbard, DJ Cantillon - … England Journal of …, 2023 - Mass Medical Soc
Background Single-chamber ventricular leadless pacemakers do not support atrial pacing
or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system …

Cardiac implantable electronic device infections: presentation, management, and patient outcomes

KG Tarakji, EJ Chan, DJ Cantillon, AL Doonan, T Hu… - Heart rhythm, 2010 - Elsevier
BACKGROUND: Indications for cardiac implantable electronic devices (CIEDs) are increasing.
Although CIED infections occur infrequently, the impact of this outcome is expected to be …

Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions

…, C Yu, KG Tarakji, DO Martin, T Callahan, DJ Cantillon… - Heart Rhythm, 2014 - Elsevier
Background It is difficult to predict adverse patient outcomes associated with transvenous
lead extraction (TLE) procedures. Objective The purpose of this study was to examine the …